internal ID number 9188 transmission ID number 20623 transmission IMEI number ****** transmission type IRIDIUM instrument type IRIDIUM program number n/a WMO ID number 5906557 WMO instrument type (table 1770) 846 WMO recorder type (table 4770) 64 start time [dd mm yyyy hh mm (Z)] 06 01 2023 19 26 status of start time as estimated launch time [dd mm yyyy hh mm (Z)] 06 01 2023 19 26 status of launch time as estimated launch position [lat latm lon lonm] -67 -0.8 -135 -1.0 status of launch position as estimated delay of first down time [hours] 0.0 down time [days] -999. up time [hours] -999. transmission repetition rate [sec] -999. clock drift [hours/hours] 0. last cycle n/a ======================================== calib eq 1 for salinity sslope*cnts+soff calib coef for salinity SSLOPE=0.001; SOFF=0.0; calib eq 1 for temperature tslope*cnts+toff calib coef for temperature TSLOPE=0.001; TOFF=0.0; calib eq 1 for pressure pslope*cnts+poff calib coef for pressure PSLOPE=0.1; POFF=0.0; calib eq 1 for oxygen o2=[1 d d^2 d^3 d^4 d^5]*c*[1 T2 T2^2 T2^3 T2^4 T2^5]' calib coef for O2 matrix c00=4.547302E+03; c01=-4.453296E+01; c02=-1.936771E-01; c03=2.230949E-02; c04=-4.134188E-04; c05=1.497347E-06; calib coef for O2 matrix c10=-3.815226E+02; c11=2.968714E+00; c12=-4.551691E-03; c13=-3.449760E-04; c14=5.200052E-06; c15=0.000000E+00; calib coef for O2 matrix c20=1.384506E+01; c21=-7.820107E-02; c22=2.077827E-04; c23=1.951742E-07; c24=0.000000E+00; c25=0.000000E+00; calib coef for O2 matrix c30=-2.623883E-01; c31=9.495663E-04; c32=-1.385170E-06; c33=0.000000E+00; c34=0.000000E+00; c35=0.000000E+00; calib coef for O2 matrix c40=2.539297E-03; c41=-4.429471E-06; c42=0.000000E+00; c43=0.000000E+00; c44=0.000000E+00; c45=0.000000E+00; calib coef for O2 matrix c50=-9.934120E-06; c51=0.000000E+00; c52=0.000000E+00; c53=0.000000E+00; c54=0.000000E+00; c55=0.000000E+00; calib eq for DPhase DPhase = p0 + p1*(TPhase + p2*(TPhase + p3*TPhase)) calib coef for DPhase p0=-5.880000E-01; p1=1.000000E+00; p2=0.000000E+00; p3=0.000000E+00; calib eq 1 for voltage vslope*cnts+voff calib coef for voltage VSLOPE=0.0700; VOFF=0.2557 calib eq 1 for vacuum vacslope*cnts+vacoff calib coef for vacuum VACSLOPE=0.0579; VACOFF=-0.00197 calib eq 1 for current islope*cnts+ioff calib coef for current ISLOPE=3.9063; IOFF=-0.0135 ======================================== conductivity calibration date 23 02 2021 temperature calibration date 23 02 2021 pressure calibration date 15 02 2021 float manufacturer Teledyne Webb Research float serial number 9257 Project name UW, SOCCOM PI Stephen Riser/Ken Johnson principal investigator address UW, Seattle, WA/MBARI, Monterey, CA originating country USA float deployer Mason Schettig float deployer address San Diego, CA deployment type R/V deployment platform Revelle deployment cruise id n/a profile at deployment n/a nominal drift pressure [dbar] 1000 cycles for drift pressure 1 nominal profile pressure [dbar] 2020 cycles for profile pressure 1 Profile Sampling Method mixed [deep: discrete, shallow:continuous] Profile Sampling Method(2) discrete pump type 260ml conductivity sensor type SBE41CP conductivity sensor manufacturer SBE conductivity sensor serial number 13782 temperature sensor type SBE41CP temperature sensor manufacturer SBE temperature sensor serial number 13782 pressure sensor type 2900 PSIA pressure sensor manufacturer DRUCK pressure sensor serial number 11695224 oxygen sensor manufacturer Aanderaa oxygen sensor height [m] 0.15 oxygen sensor type 4330 oxygen sensor serial number 3573 nitrate sensor manufacturer Monterey Bay Aquarium Research Institute nitrate sensor type ISUS nitrate sensor serial number 0995 ph sensor manufacturer Monterey Bay Aquarium Research Institute ph sensor type DURA ph sensor serial number 0995 fluoro CHLA sensor manufacture WetLabs Inc fluoro CHLA sensor type ECO_FLBB_AP2 fluoro CHLA sensor serial number 7090 fluoro BBP700 sensor manufacturer WetLabs Inc fluoro BBP700 sensor type ECO_FLBB_AP2 fluoro BBP700 sensor serial number 7090 battery type Lithium initial battery voltage [volt] 15.1 ROM version 120521 Board serial number 20623 Board version APF11 comment Apf11Sbe41cpOptodeIsusPhFlbb