internal ID number                      9187
transmission ID number                  20602
transmission IMEI number                ******
transmission type                       IRIDIUM
instrument type                         
IRIDIUM program number                  n/a
WMO ID number                           5906556
WMO instrument type (table 1770)        846
WMO recorder type (table 4770)          64
start time [dd mm yyyy hh mm (Z)]       04 01 2023 19 18
status of start time                    as estimated
launch time [dd mm yyyy hh mm (Z)]      04 01 2023 19 18
status of launch time                   as estimated
launch position [lat latm lon lonm]     -65 -1.1 -138 -57.6
status of launch position               as estimated
delay of first down time [hours]        0.0
down time [days]                        -999.
up time [hours]                         -999.
transmission repetition rate [sec]      -999.
clock drift [hours/hours]               0.
last cycle                              n/a
========================================
calib eq 1 for salinity                 sslope*cnts+soff
calib coef for salinity                 SSLOPE=0.001; SOFF=0.0;
calib eq 1 for temperature              tslope*cnts+toff
calib coef for temperature              TSLOPE=0.001; TOFF=0.0;
calib eq 1 for pressure                 pslope*cnts+poff
calib coef for pressure                 PSLOPE=0.1; POFF=0.0;
calib eq 1 for oxygen                   o2=[1 d d^2 d^3 d^4 d^5]*c*[1 T2 T2^2 T2^3 T2^4 T2^5]'
calib coef for O2 matrix                c00=4.547302E+03; c01=-4.453296E+01; c02=-1.936771E-01; c03=2.230949E-02; c04=-4.134188E-04; c05=1.497347E-06;
calib coef for O2 matrix                c10=-3.815226E+02; c11=2.968714E+00; c12=-4.551691E-03; c13=-3.449760E-04; c14=5.200052E-06; c15=0.000000E+00;
calib coef for O2 matrix                c20=1.384506E+01; c21=-7.820107E-02; c22=2.077827E-04; c23=1.951742E-07; c24=0.000000E+00; c25=0.000000E+00;
calib coef for O2 matrix                c30=-2.623883E-01; c31=9.495663E-04; c32=-1.385170E-06; c33=0.000000E+00; c34=0.000000E+00; c35=0.000000E+00;
calib coef for O2 matrix                c40=2.539297E-03; c41=-4.429471E-06; c42=0.000000E+00; c43=0.000000E+00; c44=0.000000E+00; c45=0.000000E+00;
calib coef for O2 matrix                c50=-9.934120E-06; c51=0.000000E+00; c52=0.000000E+00; c53=0.000000E+00; c54=0.000000E+00; c55=0.000000E+00;
calib eq   for DPhase                   DPhase = p0 + p1*(TPhase  + p2*(TPhase  + p3*TPhase))
calib coef for DPhase                   p0=-6.010000E-01; p1=1.000000E+00; p2=0.000000E+00; p3=0.000000E+00;
calib eq 1 for voltage                  vslope*cnts+voff
calib coef for voltage                  VSLOPE=0.0701; VOFF=0.2047
calib eq 1 for vacuum                   vacslope*cnts+vacoff
calib coef for vacuum                   VACSLOPE=0.0575; VACOFF=0.08501
calib eq 1 for current                  islope*cnts+ioff
calib coef for current                  ISLOPE=3.9055; IOFF=0.0155
========================================
conductivity calibration date           20 04 2021
temperature calibration date            20 04 2021
pressure calibration date               04 05 2021
float manufacturer                      Teledyne Webb Research
float serial number                     9253
Project name                            UW, SOCCOM
PI                                      Stephen Riser/Ken Johnson
principal investigator address          UW, Seattle, WA/MBARI, Monterey, CA
originating country                     USA
float deployer                          Mason Schettig
float deployer address                  San Diego, CA
deployment type                         R/V
deployment platform                     Revelle
deployment cruise id                    n/a
profile at deployment                   n/a
nominal drift pressure [dbar]           1000
cycles for drift pressure               1
nominal profile pressure [dbar]         2020
cycles for profile pressure             1
Profile Sampling Method                 mixed [deep: discrete, shallow:continuous]
Profile Sampling Method(2)              discrete
pump type                               260ml
conductivity sensor type                SBE41CP
conductivity sensor manufacturer        SBE
conductivity sensor serial number       13778
temperature sensor type                 SBE41CP
temperature sensor manufacturer         SBE
temperature sensor serial number        13778
pressure sensor type                    2900 PSIA
pressure sensor manufacturer            DRUCK
pressure sensor serial number           11691122
oxygen sensor manufacturer              Aanderaa
oxygen sensor height [m]                0.15
oxygen sensor type                      4330
oxygen sensor serial number             3569
nitrate sensor manufacturer             Monterey Bay Aquarium Research Institute
nitrate sensor type                     ISUS
nitrate sensor serial number            0989
ph sensor manufacturer                  Monterey Bay Aquarium Research Institute
ph sensor type                          DURA
ph sensor serial number                 0989
fluoro CHLA sensor manufacture          WetLabs Inc
fluoro CHLA sensor type                 ECO_FLBB_AP2
fluoro CHLA sensor serial number        7050
fluoro BBP700 sensor manufacturer       WetLabs Inc
fluoro BBP700 sensor type               ECO_FLBB_AP2
fluoro BBP700 sensor serial number      7050
battery type                            Lithium
initial battery voltage [volt]          15.1
ROM version                             120521
Board serial number                     20602
Board version                           APF11
comment                                 Apf11Sbe41cpOptodeIsusPhFlbb