internal ID number 7674 transmission ID number 12688 transmission IMEI number ****** transmission type IRIDIUM instrument type IRIDIUM program number n/a WMO ID number 5905991 WMO instrument type (table 1770) 846 WMO recorder type (table 4770) 64 start time [dd mm yyyy hh mm (Z)] 28 01 2019 01 37 status of start time as estimated launch time [dd mm yyyy hh mm (Z)] 28 01 2019 01 37 status of launch time as estimated launch position [lat latm lon lonm] -64 -10.3 -47 -28.7 status of launch position as estimated delay of first down time [hours] 0.0 down time [days] -999. up time [hours] -999. transmission repetition rate [sec] -999. clock drift [hours/hours] 0. last cycle n/a ======================================== calib eq 1 for salinity sslope*cnts+soff calib coef for salinity SSLOPE=0.001; SOFF=0.0; calib eq 1 for temperature tslope*cnts+toff calib coef for temperature TSLOPE=0.001; TOFF=0.0; calib eq 1 for pressure pslope*cnts+poff calib coef for pressure PSLOPE=0.1; POFF=0.0; calib eq 1 for oxygen o2=[1 d d^2 d^3 d^4 d^5]*c*[1 T2 T2^2 T2^3 T2^4 T2^5]' calib coef for O2 matrix c00=3.814899E+03; c01=-3.222806E+01; c02=-1.678000E-01; c03=1.894820E-02; c04=-6.901433E-04; c05=1.042693E-05; calib coef for O2 matrix c10=-3.143506E+02; c11=2.051116E+00; c12=-2.987026E-03; c13=-4.449771E-06; c14=-1.861349E-06; c15=0.000000E+00; calib coef for O2 matrix c20=1.118020E+01; c21=-5.148064E-02; c22=6.898503E-05; c23=8.465012E-07; c24=0.000000E+00; c25=0.000000E+00; calib coef for O2 matrix c30=-2.072853E-01; c31=6.012464E-04; c32=-6.604266E-07; c33=0.000000E+00; c34=0.000000E+00; c35=0.000000E+00; calib coef for O2 matrix c40=1.960006E-03; c41=-2.679283E-06; c42=0.000000E+00; c43=0.000000E+00; c44=0.000000E+00; c45=0.000000E+00; calib coef for O2 matrix c50=-7.483597E-06; c51=0.000000E+00; c52=0.000000E+00; c53=0.000000E+00; c54=0.000000E+00; c55=0.000000E+00; calib eq for DPhase DPhase = p0 + p1*(TPhase + p2*(TPhase + p3*TPhase)) calib coef for DPhase p0=2.920000E-01; p1=1.000000E+00; p2=0.000000E+00; p3=0.000000E+00; calib eq 1 for voltage vslope*cnts+voff calib coef for voltage VSLOPE=0.0778; VOFF=0.5454 calib eq 1 for vacuum vacslope*cnts+vacoff calib coef for vacuum VACSLOPE=0.1436; VACOFF=-0.12685 calib eq 1 for current islope*cnts+ioff calib coef for current ISLOPE=4.0515; IOFF=-1.1153 ======================================== conductivity calibration date 04 11 2017 temperature calibration date 04 11 2017 pressure calibration date 02 11 2017 float manufacturer Teledyne Webb Research float serial number 8301 Project name UW, SOCCOM, Argo equivalent PI Stephen Riser principal investigator address UW, Seattle originating country USA float deployer Paul Chamberlain float deployer address Scripps Institute, San Diego, California, USA deployment type R/V deployment platform Polarstern deployment cruise id n/a profile at deployment n/a nominal drift pressure [dbar] 1000 cycles for drift pressure 1 nominal profile pressure [dbar] 2020 cycles for profile pressure 1 Profile Sampling Method mixed [deep: discrete, shallow:continuous] Profile Sampling Method(2) discrete pump type 260ml conductivity sensor type SBE41CP conductivity sensor manufacturer SBE conductivity sensor serial number 10229 temperature sensor type SBE41CP temperature sensor manufacturer SBE temperature sensor serial number 10229 pressure sensor type 2900 PSIA pressure sensor manufacturer DRUCK pressure sensor serial number 10733379 oxygen sensor manufacturer Aanderaa oxygen sensor height [m] 0.15 oxygen sensor type 4330 oxygen sensor serial number 2847 nitrate sensor manufacturer Monterey Bay Aquarium Research Institute nitrate sensor type ISUS nitrate sensor serial number 0822 ph sensor manufacturer Monterey Bay Aquarium Research Institute ph sensor type DURA ph sensor serial number 0822 fluorometer sensor manufacturer WetLabs Inc fluorometer sensor type ECO_FLBB_AP2 fluorometer sensor serial number 4672 battery type Lithium initial battery voltage [volt] 15.1 ROM version 121915 Board serial number 12688 Board version APF9 comment Apf9iSbe41cpOptodeIsusPhFlbb