% Float Information file for Float WMO 5906526; FLOAT.F5906526.WMO = '5906526'; FLOAT.F5906526.OperatorFLID = '20108'; FLOAT.F5906526.Operators = 'UW'; FLOAT.F5906526.OperatorMetaln = '5906526_meta.html'; FLOAT.F5906526.status = {'blad
220613','1'}; % {'txt','num:2=not_deployed;1=active;0=dead'} FLOAT.F5906526.Ftype = 'Apex'; FLOAT.F5906526.sensors = 'IONpF'; % IONpFM; use M for Navis CDOM fluorometer FLOAT.F5906526.sensor_pressure = {'-999','-999','-999'}; % {'mfg','type','sn'} FLOAT.F5906526.sensor_temperature = {'-999','-999','-999'}; % {'mfg','type','sn'} FLOAT.F5906526.sensor_conductivity = {'-999','-999','-999'}; % {'mfg','type','sn'} FLOAT.F5906526.sensor_oxygen = {'-999','-999','-999'}; % {'mfg','type','sn'} FLOAT.F5906526.sensor_nitrate = {'-999','-999','-999'}; % {'mfg','type','sn'} FLOAT.F5906526.sensor_pH = {'-999','-999','-999'}; % {'mfg','type','sn'} FLOAT.F5906526.sensor_fluorometer = {'-999','-999','-999'}; % {'mfg','type','sn'} FLOAT.F5906526.sensor_fluoroCHLA = {'-999','-999','-999'}; % {'mfg','type','sn'} FLOAT.F5906526.sensor_fluoroBBP700 = {'-999','-999','-999'}; % {'mfg','type','sn'} FLOAT.F5906526.sensor_cdom = {'-999','-999','-999'}; % {'mfg','type','sn'} FLOAT.F5906526.ship = 'Agulhas II'; FLOAT.F5906526.shipCruise = 'Marion_Island'; FLOAT.F5906526.CRID = 'Marion_Island'; % program cruise ID, example SOCCOM FLOAT.F5906526.EXPOCODE = '91AH20220417'; FLOAT.F5906526.ctdFNAME = '-999'; FLOAT.F5906526.botFNAME = '-999'; FLOAT.F5906526.STNNBR = '1274'; %'AM01274'; FLOAT.F5906526.launchDATE = '20220508'; % deployment email FLOAT.F5906526.launchTIME = '0828'; % deployment email FLOAT.F5906526.launchLAT = '47.7461'; % deployment email FLOAT.F5906526.launchLON = '37.3054'; % deployment email FLOAT.F5906526.CASTNO = '1'; % guessing FLOAT.F5906526.ctdDATE = '-999'; FLOAT.F5906526.ctdTIME = '-999'; FLOAT.F5906526.ctdLAT = '-999'; FLOAT.F5906526.ctdLON = '-999'; FLOAT.F5906526.NOTES = {'2022-06-10:bladder:has a stuck pneumatic bladder that prevents inflation and results in poor telemetry.',... '2023-04-20:CPmode:Modified cp-mode activation depth to 1585m which will improve the accuracy & integrity of the pH profiles by eliminating the discontinuity at 985m in various pH profiles. The discontinuity presents difficulty for QC'}; % {'date:tag:text','date:dat:text'} FLOAT.F5906526.Adopt = {'Pacific Law Academy','Stockton','CA','The Pacific Tiger','no image' }; %% {'school','city','state','name','link'} FLOAT.F5906526.CCHDOln = 'https://cchdo.ucsd.edu/cruise/xxxxxxxxxxxx'; FLOAT.F5906526.EuroArgoln = 'http://fleetmonitoring.euro-argo.eu/float/5906526'; FLOAT.F5906526.comment = '-999';